MT Micro 10/6 HDPE

Microduct for direct buried

  • Recommended cable dimens for blowing from 1,8 to 4,2 mm
Product enquiry Download datasheet
Temperature range to EN 60794-1-22-F1 Installation -10°C to +50°C, Operation -40°C to +70°C, Storage -40°C to +70°C
Outer diameter (OD) 10 ± 0.1 mm
Ovality max. 5%
Inner coefficient of friction max. 0,1
Thermal expansion *1,6*10-4 K-1 ISO 11359-2 (-20°C to +70°C)
Longitudinal reversion max. 3% ČSN EN ISO 2505
Weight 47,5 kg/km
Installation tensile force max. 680N
Minimum bending radius 100 mm
Blowing pressure max. 20 bar
Wall thickness (WT) min. 1,9 mm
inner diameter (ID) min. 5,9 mm
Burst pressure min. 70 bar
Crush - pressure force min. 1000N
Crush - residual deformation max. 15% OD = max. 1,5 mm
Impact No damage after the test, dimens in tolerances after recovery
Bending stiffness min. 0,19 Nm2
Blown ball test (BB test) Pass
Na vyžádání On request