MT Micro 16/12 HDPE

Microduct for direct buried

  • Recommended cable dimens for blowing from 3,6 to 8,4 mm
Product enquiry Download datasheet
Temperature range to EN 60794-1-22-F1 Installation -10°C to +50°C, Operation -40°C to +70°C, Storage -40°C to +70°C
Outer diameter (OD) 16 ± 0.1 mm
Ovality max. 5%
Inner coefficient of friction max. 0,1
Visual examination free from defects
Thermal expansion *1,6*10-4 K-1 ISO 11359-2 (-20°C to +70°C)
Longitudinal reversion max. 3% ČSN EN ISO 2505
Weight 84 kg/km
Installation tensile force max. 1150N
Minimum bending radius 160 mm
Blowing pressure max. 20 bar
Wall thickness (WT) min. 1,9 mm
inner diameter (ID) min.11,9 mm
Burst pressure min. 40 bar
Crush - pressure force min. 1000N
Crush - residual deformation max. 15% OD = max. 2,4 mm
Impact No damage after the test, dimens in tolerances after recovery
Bending stiffness min. 0,94 Nm2
Blown ball test (BB test) Pass
Na vyžádání On request